CAP-4-US

The award-winning, CAP-4-US comes equipped with a square 4” IR window and an ultrasound port both on one easy-to-install panel. The viewing area of the CAP-4-US offers a 30% increase in FOV over round windows but also provides a method for accessing quality acoustics data that easily identifies potentially hazardous faults such as arcing, tracking and corona in electrical distribution systems and switchgear.

A Multi-Technology Approach to Energized Electrical Inspections

  • Integrates Sight & Sound on One Easy-to-Install Window

    The CAP-4-US comes equipped with a square 4” IR window and an ultrasound port both on one easy-to-install panel

  • Unparalleled Field of View

    The viewing area of the CAP-4-US offers a 30% increase in FOV over traditional round windows and provides precisely-focused acoustic data.

  • Combines Visual, Ultrasound and Infrared

    The CAP-4-US combines visual, ultrasound and infrared to an IR window that easily identifies potentially hazardous faults such as arcing, tracking and corona in electrical in electrical distribution systems and switchgear.

Our Strong Points Ipad
  • Durable, Fully Impact-Resistant

    IRISS IR windows do not degrade when exposed to acids, alkalis, UV, moisture, humidity, vibration and high frequency noise – a guarantee no crystal IR window can provide.

  • Certified

    IRISS IR windows are the most certified windows in the industry with IEEE (impact & load), UL, cUL, Lloyds, CSA 22.2 14-13 for industrial control equipment, DNV and ABS (American Bureau of Shipping) credentials.

  • Proudly Made in the United States

    IRISS manufactures and assembles all products at our global headquarters located in Bradenton, FL.

Specifications

Materials
Window Housing and CoverStandard product constructed of aluminum; custom materials available
OpticUL 746 compliant, visual, UV and IR transmissive polymer; -40°C (-40°F) to 325°C (617°F)
GasketsUL 94 5VA TPE; -40°C (-40°F) to 273°C (523°F)
Hardware316 stainless steel
Other
Useful Temperature Rating-40°C (-40°F) to 200°C (392°F)
Water and Dust IngressIP65 / NEMA 4
ModelWindow DimensionsOverall Dimensions
CAP-C-4-USA= 9.68 cm (3.81 in), B= 9.77 cm (3.85 in)C= 15.24 cm (6 in), D= 25.4 cm (10 in)
CAP-CT-4-USA= 9.68 cm (3.81 in), B= 9.77 cm (3.85 in)C= 15.24 cm (6 in), D= 25.4 cm (10 in)

Tested and Certified to The Highest Industry Standards

IRISS IR windows are the most certified windows in the industry with IEEE (impact & load), UL, cUL, Lloyds and CSA C22.2 14-13 for industrial control equipment Check out this product certifications!

  • UL 50V

    UL 50V applies to infrared windows and is more of a classification than a standard that applies for performance-of-build characteristics.

  • CSA C22.2 No. 14-10

    Canadian Standards Association shows that a product has been independently tested and certified to meet recognizable standards for safety and performance.

  • UL 508 & 508A

    UL 508 and UL 508A are classification for the components used on electrical panels. UL 746C is a standard requiring flammability and impact tests for polymeric materials used on electrical equipment.

  • IP65/NEMA 4

    These equivalent ratings certify enclosures for indoor or outdoor use. They protect against access to hazardous parts, ingress of foreign objects and water from rain, sleet, snow, splashing or hose directed water & ice formation damage.

  • UL 50E

    UL 50E standard applies to enclosures for electrical equipment intended to be installed and used in non-hazardous locations.

  • Lloyd’s of London

    Lloyd’s provides independent, third-party approval certificates attesting to a product’s conformity with specific standards or specifications. It verifies the manufacturer’s production quality systems through a combination of design reviews and type testing.

  • UL 1558

    Requirement covers metal-enclosed, low-voltage power circuit breaker switchgear assemblies containing but not limited to low-voltage power circuit breakers, switches, control, instrumentation and metering, protective and regulating equipment.

  • American Burea of Shipping

    An ABS assessment is the pre-approval of a product for use on a variety of ABS- classed ships following a technical evaluation. Ship designers, builders and owners can select the product to be placed aboard and ABS-classed vessel.

  • UL 746C

    Sets the impact & flammability standards for polymer materials used in electrical equipment to 1500 volts. Plastic/polymer parts of an IR window must pass flammability tests at room temperature & remain intact during an impact test performed at 0°C (32°F).

  • DNV

    DNV Certification is awarded for marine and offshore applications and allows preventative maintenance on electrical equipment in these vertical markets. DNV covers Rules for Classification of Ships and Offshore Standards (vessels, tankers, military and cruise ships, and oil drilling riggs).

  • IEEE C37 20.2a.3.6

    The IEEE C37 20.2 Section 3.6 is the impact and load requirement for all viewing panes installed on medium and high voltage switchgear. Panes made from crystal of glass will not pass these requirements.